setup

Proxmox SR-IOV Setup for Intel Arc Pro B50 and B60

Set up Intel Arc Pro B50 or B60 SR-IOV on Proxmox. Check firmware and VF limits, bind a virtual function to VFIO, and verify it in a Linux VM.

Illustrated title card for the guide: Proxmox SR-IOV Setup for Intel Arc Pro B50 and B60

To set up SR-IOV on Proxmox with an Intel Arc Pro B50 or B60 that exposes virtual functions, keep the physical GPU on the host’s xe driver. Create a virtual function (VF), bind it to vfio-pci, and attach that VF to a Linux VM as a PCI device. Intel SR-IOV overview, Proxmox PCI passthrough

Check the kernel, card and firmware

Use this procedure on an Intel-based Proxmox host with an existing Linux VM. Intel’s SR-IOV instructions call for Linux 6.17 or later on the host and guest. Proxmox announced an end-of-July 2026 support cutoff for its 6.17 kernel series. Proxmox VE 9.3 ships with Linux 7.0 as the stable default. Intel host setup, Intel Linux guest setup, Proxmox kernel support notice, Proxmox VE 9.3 announcement

Before running the host checks, install the required GPU software packages from the latest Intel Open Middleware Xe (OMIX) release and install xpu-smi. Follow the installation requirements linked in Intel’s host setup. Intel host prerequisites

Match the physical card by its device ID. After boot, use the lower of the hardware limit reported by sriov_totalvfs and the configured xe.max_vfs cap. Intel Xe driver device IDs, Intel host setup

GPUDevice IDCard memoryVF limit to use
Arc Pro B50e21216 GB GDDR6Lower of sriov_totalvfs and xe.max_vfs.
Arc Pro B60e21124 GB GDDR6Lower of sriov_totalvfs and xe.max_vfs.

Intel card specifications

Run these checks in the Proxmox host’s root shell. The last command shows the version of the GuC firmware loaded by xe. Proxmox kernel check, Intel PCI device discovery, Intel GuC check

uname -r
lspci -nn | grep -iE 'VGA|Display controller'
dmesg | grep -E 'GuC' | grep version

Compare the reported GuC version with the readiness criteria under Updating firmware in Intel’s host setup. If the guide calls for an update, follow its firmware instructions and rerun the GuC check after reboot. Intel GuC readiness and updates

Proxmox updates the runtime firmware included in pve-firmware through its regular system updates. For firmware stored on the graphics card, look up an update for the exact Arc Pro SKU. Proxmox firmware updates, Intel graphics firmware instructions

Enable SR-IOV on the host

In the host’s BIOS or UEFI, enable Intel VT-x, Intel VT-d, SR-IOV Support, Re-Size BAR Support and Above 4G Decoding. Setting names and locations vary by motherboard. Save the settings. Intel BIOS setup

Use efibootmgr -v as an initial bootloader check. If the output is ambiguous, watch the node boot before editing its boot configuration. Proxmox identifies watching the boot process as the most reliable check. Proxmox documents GRUB entries pointing to grubx64.efi or shimx64.efi and systemd-boot pointing to systemd-bootx64.efi. If the command reports that EFI variables are unsupported, Proxmox uses GRUB in legacy BIOS mode. Proxmox system booting

Append the following kernel options to the existing boot parameters. xe.max_vfs=2 permits up to two VFs per GPU in this example. The card can expose fewer. To allow for more VFs per GPU, raise the cap and check sriov_totalvfs after rebooting. Intel kernel parameters

intel_iommu=on iommu=pt xe.max_vfs=2
BootloaderWhere to append the optionsCommand to apply the edit
GRUBInside GRUB_CMDLINE_LINUX_DEFAULT in /etc/default/grubupdate-grub
systemd-bootOn the existing line in /etc/kernel/cmdlineproxmox-boot-tool refresh

Reboot the host after applying the change. In the Proxmox root shell, check the active kernel parameters and host log. Proxmox kernel command line, Intel host verification

cat /proc/cmdline
dmesg | grep -iE 'DMAR: IOMMU enabled|Directed I/O'
dmesg | grep -i sr-iov

Confirm the IOMMU log reports that VT-d is enabled. Look for Running in SR-IOV PF mode on the line for your card. Use the full PCI address from that line in place of the example PF value below. Continue if the lower of the reported VF limit and the active xe.max_vfs cap is positive. Otherwise, revisit BIOS settings, the kernel options and the card’s firmware. Intel host verification, Intel graphics firmware instructions

PF=0000:17:00.0
cat "/sys/bus/pci/devices/$PF/sriov_totalvfs"

Create and bind one VF

Start with one VF, using the PF value from the previous step. These commands assume a fresh allocation. Disable driver auto-probe before creating the VF so the host’s xe driver leaves it available for passthrough. Check the kernel log for the PF’s enabled VF count before binding the VF. Intel VF provisioning

echo 0 | tee "/sys/bus/pci/devices/$PF/sriov_drivers_autoprobe"
echo 1 | tee "/sys/bus/pci/devices/$PF/sriov_numvfs"
dmesg | grep -iE 'PF: Enabled|provisioned with'

Compare this PCI listing with the host check above to identify the new VF. Include the PCI domain in its address, as in the example below. Then use that address as VF in the binding commands. Intel VF address discovery

lspci -nn | grep -iE 'vga|display'

Bind by PCI address so vfio-pci claims only the selected function. Confirm the VF is bound to the passthrough driver and the PF to xe. Intel VF binding and verification

VF=0000:17:00.1
modprobe vfio-pci
echo vfio-pci | tee "/sys/bus/pci/devices/$VF/driver_override"
echo "$VF" | tee /sys/bus/pci/drivers_probe
lspci -k -s "$VF"
lspci -k -s "$PF"

Attach the VF to the Proxmox VM

Replace YOUR_NODE with the Proxmox node name. Locate the VF in the PCI list and check its IOMMU group. Proceed when the VF is isolated from other endpoints. Proxmox allows a device to share its group with its root port or bridge. Proxmox IOMMU group checks

pvesh get /nodes/YOUR_NODE/hardware/pci --pci-class-blacklist ""

Use a stopped VM with the q35 machine type, which supports PCIe passthrough. Replace the example VM ID and use an unused hostpci slot. Include the function suffix in the VF address so qm selects only that PCI function. Proxmox VM PCI configuration

VMID=100
qm set "$VMID" -hostpci0 "$VF",pcie=on

After attaching the VF, start the VM. Intel guest setup

Verify the VF inside Linux

Inside the guest, install the required Intel GPU software packages and xpu-smi using the installation guidance linked from Intel’s host setup. Intel guest prerequisites, Intel host prerequisites

Run these commands inside the guest. Look for the Intel GPU in lspci and Running in SR-IOV VF mode in the log. If the PCI device appears but xe does not initialize it, check the guest kernel with uname -r. Intel documents this symptom on the Ubuntu 24.04 cloud image with its 6.8 kernel. Intel guest verification, Proxmox kernel check

uname -r
lspci | grep -iE 'vga|display'
sudo dmesg | grep -iE 'SR-IOV|VRAM\[0\]'

For a guest using the Ubuntu 24.04 cloud image, Intel’s guide uses the hardware enablement (HWE) kernel if installing the GPU software leaves the guest below 6.17. Install it in the guest, reboot the guest, then repeat the checks. The guest still needs the Intel GPU software packages and xpu-smi. Intel guest kernel instructions

sudo apt update && sudo apt install -y linux-generic-hwe-24.04
sudo reboot

Recreate VFs after reboot or remove them

The VFs are removed when the host reboots. With this manual setup, keep the VM stopped after a host reboot. Start it only after you recreate the VF, bind it to the passthrough driver, and verify that its PCI address matches the VM configuration. Intel VF lifecycle

Before removing or changing the VF count, shut down every VM using a VF from that card. To undo the single-VM example, find the hostpci0 entry for 0000:17:00.1 with pcie=on. Verify that the PCI address in the entry matches the VF you assigned before removing the entry. Then remove the card’s VFs and restore driver auto-probe. Use the PF value from your own setup. Proxmox VM PCI configuration, Intel GPU VM lifecycle

echo 0 | tee "/sys/bus/pci/devices/$PF/sriov_numvfs"
echo 1 | tee "/sys/bus/pci/devices/$PF/sriov_drivers_autoprobe"

Evidence and limits. Intel Xe GPU Software’s Linux 6.17+ SR-IOV instructions and the Proxmox VE documentation and 9.3 release notes were checked on November 26, 2026. The procedure was assembled from documentation and was not run on hardware.

Sources

  1. Intel Xe GPU Software: Virtualization with SR-IOV dgpu-docs.intel.com
  2. Intel Xe GPU Software: Preparing the System for SR-IOV dgpu-docs.intel.com
  3. Intel Xe GPU Software: Enabling SR-IOV Virtual Functions dgpu-docs.intel.com
  4. Intel Arc Pro B-Series Graphics Architecture dgpu-docs.intel.com
  5. Intel Xe Kernel Driver GPU IDs dgpu-docs.intel.com
  6. Intel XPU Manager 2.0: Graphics Firmware Updates intel.github.io
  7. Proxmox VE 9.3 Release Announcement proxmox.com
  8. Proxmox VE Linux 6.17 End of Support forum.proxmox.com
  9. Proxmox VE System Booting github.com
  10. Proxmox VE Firmware Updates github.com
  11. Proxmox VE PCI(e) Passthrough github.com
  12. Intel Xe GPU Software: Creating and Configuring VMs with GPU VFs dgpu-docs.intel.com
  13. Intel Xe GPU Software: Managing GPU Virtual Machines dgpu-docs.intel.com